{"id":4865,"date":"2025-03-13T04:10:49","date_gmt":"2025-03-13T04:10:49","guid":{"rendered":"http:\/\/localhost:8080\/microengine\/?page_id=4865"},"modified":"2026-05-05T17:46:44","modified_gmt":"2026-05-05T09:46:44","slug":"xp-q1200i-se","status":"publish","type":"page","link":"https:\/\/mewebapp-dev.com\/my\/controller\/qr-access-controller\/xp-q1200i-se\/","title":{"rendered":"XP-Q1200i-SE"},"content":{"rendered":"<h2>XP-Q1200i-SE&nbsp;1 Door IP Access Controller<\/h2>\n<div id=\"line\"><\/div>\n<p align=\"center\"><a href=\"\/wp-content\/uploads\/sites\/4\/2025\/03\/XP-Q1200i-SE.png\" rel=\"lightbox-0\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-4741\" src=\"\/wp-content\/uploads\/sites\/4\/2025\/03\/XP-Q1200i-SE.png\" alt=\"\" width=\"400\" height=\"367\"><\/a><\/p>\n<div id=\"content-bg\">\n<p>The XP-Q1200i-SE Controller is a single door encrypted IP DESFire QR access controller presented in DIN Rail form factor. It is equipped with technology supporting MIFARE<br \/>\nDESFire EV2 and Dynamic QR Code access methods.<\/p>\n<ul class=\"list2\">\n<li>DESFire Support<\/li>\n<li>Support 64 bit Card ID<\/li>\n<li>Dual ID Matching<\/li>\n<li>Support MicroEngine Mobile<br \/>\nAccess App<\/li>\n<li>Support QR Code Reader<\/li>\n<\/ul>\n<\/div>\n<div class=\"su-tabs su-tabs-style-default su-tabs-mobile-stack\" data-active=\"1\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-tabs-nav\"><span class=\"\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">Features<\/span><span class=\"\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">Configuration Diagram<\/span><span class=\"\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">Documentation<\/span><span class=\"\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">FAQ<\/span><\/div><div class=\"su-tabs-panes\"><div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"Features\">\n<table class=\"product_1\" style=\"height: 387px;\" border=\"0\" width=\"1165\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"product_1_bg\">\n<td class=\"table_no2\">No<\/td>\n<td>Item<\/td>\n<td>Features<\/td>\n<\/tr>\n<tr>\n<td>1.<\/td>\n<td>Card Holder Size<\/td>\n<td>20,000 (Card Length: 20 Digits)<\/td>\n<\/tr>\n<tr>\n<td>2.<\/td>\n<td>Max Transactions Log<\/td>\n<td>50,000<\/td>\n<\/tr>\n<tr>\n<td>3.<\/td>\n<td>Connect to Software<\/td>\n<td>TCP\/IP<\/td>\n<\/tr>\n<tr>\n<td>4.<\/td>\n<td>Connect to Reader<\/td>\n<td>Max. 2 (PLATO Reader, 1 Entry &amp; 1 Exit)<\/td>\n<\/tr>\n<tr>\n<td>5.<\/td>\n<td>Input(s)<\/td>\n<td>4<br \/>\n1 Door Sensor + 1 Exit Button<br \/>\n1 Dedicated Fire Alarm<br \/>\n1 Dedicated Tamper Input<\/td>\n<\/tr>\n<tr>\n<td>6.<\/td>\n<td>Output(s)<\/td>\n<td>Yes, (1) support max. 12VDC, 1A<\/td>\n<\/tr>\n<tr>\n<td>7.<\/td>\n<td>Real Time Clock<\/td>\n<td>With On-Board Battery<\/td>\n<\/tr>\n<tr>\n<td>8.<\/td>\n<td>Power Fail Monitor<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>9.<\/td>\n<td>Processor<\/td>\n<td>PIC32-bit RISC MCU at 80 MHz<\/td>\n<\/tr>\n<tr>\n<td>10.<\/td>\n<td>Data Flash Memory<\/td>\n<td>EEPROM: 128 KB x 2, Flash: 4 MB<\/td>\n<\/tr>\n<tr>\n<td>11.<\/td>\n<td>Flash<\/td>\n<td>512 KB<\/td>\n<\/tr>\n<tr>\n<td>12.<\/td>\n<td>DIN-Rail Casing Dimension<\/td>\n<td>115 mm (H) x 106 mm (W) x 40 mm (D)<\/td>\n<\/tr>\n<tr>\n<td>13.<\/td>\n<td>Casing Dimension (MP-340)<\/td>\n<td>267 mm (H) x 310 mm (W) x 72 mm (D)<\/td>\n<\/tr>\n<tr>\n<td>14.<\/td>\n<td>Power Supply<\/td>\n<td>Input: 240VAC, 1A.<br \/>\nOutput: 13.8VDC, 2.8A (max).<\/td>\n<\/tr>\n<tr>\n<td>15.<\/td>\n<td>Power Consumption<\/td>\n<td>Yes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"Configuration Diagram\"><a href=\"\/wp-content\/uploads\/sites\/4\/2025\/03\/Conf_Diagram_XP-Q1200i-SE1.png\" rel=\"lightbox-1\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-4832\" src=\"\/wp-content\/uploads\/sites\/4\/2025\/03\/Conf_Diagram_XP-Q1200i-SE1.png\" alt=\"\" width=\"800\" height=\"364\"><\/a><\/div>\n<div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"Documentation\">\n<table class=\"product_1\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"product_1_bg\">\n<td class=\"table_no2\">No<\/td>\n<td>Documentation<\/td>\n<\/tr>\n<tr>\n<td>1.<\/td>\n<td><a href=\"\/pdf\/DATASHEET-2025_XP-Q1200i-SE.pdf\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"pdf_img\" src=\"\/wp-content\/uploads\/sites\/4\/2015\/04\/PDF-Icon.jpg\" alt=\"PDF-Icon\" width=\"12\" height=\"12\">&nbsp;Product Brochure: XP-Q1200i-SE<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"FAQ\">\n<p><strong style=\"font-size: 18px;\">FAQ<\/strong><\/p>\n<div class=\"su-accordion su-u-trim\">\n<div class=\"su-spoiler su-spoiler-style-simple su-spoiler-icon-plus\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span>1. I have purchased XP-M2300i and I need to\u2026<\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">\n<ul>\n<li>To install the controller, follow the wiring connection diagram provided, see article ID:&nbsp;<a href=\"\/kb\/article\/AA-00364\" target=\"_blank\" rel=\"noopener\">AA-00364<\/a><\/li>\n<li>To configure the uplink connection, see article ID:&nbsp;<a href=\"\/kb\/article\/AA-00216\" target=\"_blank\" rel=\"noopener\">AA-00216<\/a>&nbsp;if using network connection, or see article ID:&nbsp;<a href=\"\/kb\/article\/AA-00320\" target=\"_blank\" rel=\"noopener\">AA-00320<\/a>&nbsp;if using RS485 connection.<\/li>\n<\/ul>\n<\/div><\/div>\n<div class=\"su-spoiler su-spoiler-style-simple su-spoiler-icon-plus su-spoiler-closed\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span>2. I have installed XP-M2300i at my site, but how do I configure the controller<\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">\n<ul>\n<li>To reset the controller to factory default setting (Coldstart), see article ID:&nbsp;<a href=\"\/kb\/article\/AA-00304\" target=\"_blank\" rel=\"noopener\">AA-00304<\/a><\/li>\n<li>How to use Auto PIN only to access the door, see article ID:&nbsp;<a href=\"\/kb\/article\/AA-00204\" target=\"_blank\" rel=\"noopener\">AA-00204<\/a><\/li>\n<li>To configure car park application using XP-M2300i, see article ID:&nbsp;<a href=\"\/kb\/article\/AA-00342\" target=\"_blank\" rel=\"noopener\">AA-00342<\/a><\/li>\n<\/ul>\n<\/div><\/div>\n<div class=\"su-spoiler su-spoiler-style-simple su-spoiler-icon-plus su-spoiler-closed\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span>3. Troubleshooting Guide <\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">\n<ul>\n<li>Problem to set the address number for reader and controller, see article ID:&nbsp;<a href=\"\/kb\/article\/AA-00332\" target=\"_blank\" rel=\"noopener\">AA-00332<\/a><\/li>\n<li>What is the default IP address for the XP-M2300i controller, see article ID:&nbsp;<a href=\"\/kb\/article\/AA-00336\" target=\"_blank\" rel=\"noopener\">AA-00336<\/a><\/li>\n<\/ul>\n<\/div><\/div>\n<\/div>\n<h6><\/h6>\n<p>&nbsp;<\/p>\n<\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>XP-Q1200i-SE&nbsp;1 Door IP Access Controller The XP-Q1200i-SE Controller is a single door encrypted IP DESFire QR access controller presented in DIN Rail form factor. It is equipped with technology supporting MIFARE DESFire EV2 and Dynamic QR Code access methods. DESFire Support Support 64 bit Card ID Dual ID Matching Support MicroEngine Mobile Access App Support [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":4501,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"template-sidebar.php","meta":{"footnotes":""},"class_list":["post-4865","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages\/4865","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/comments?post=4865"}],"version-history":[{"count":12,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages\/4865\/revisions"}],"predecessor-version":[{"id":5885,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages\/4865\/revisions\/5885"}],"up":[{"embeddable":true,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages\/4501"}],"wp:attachment":[{"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/media?parent=4865"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}