{"id":4740,"date":"2025-02-10T11:04:07","date_gmt":"2025-02-10T11:04:07","guid":{"rendered":"http:\/\/localhost:8080\/microengine\/?page_id=4740"},"modified":"2026-05-05T17:44:12","modified_gmt":"2026-05-05T09:44:12","slug":"xp-m4l-se","status":"publish","type":"page","link":"https:\/\/mewebapp-dev.com\/my\/controller\/encrypted-ip-controller\/xp-m4l-se\/","title":{"rendered":"XP-M4L-SE"},"content":{"rendered":"<h2>XP-M4L-SE-IP Based Lift Access Controller<\/h2>\n<div id=\"line\"><\/div>\n<p align=\"center\"><a href=\"\/wp-content\/uploads\/sites\/4\/2025\/02\/XP-M4L-SE.png\" rel=\"lightbox-0\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-4725\" src=\"\/wp-content\/uploads\/sites\/4\/2025\/02\/XP-M4L-SE-300x274.png\" alt=\"\" width=\"400\" height=\"367\"><\/a><\/p>\n<div id=\"content-bg\">\n<p>XP-M4L-SE Controller IP Based Lift Access Controller is designed for lift button masking system, control up to 128 floor buttons and 4 lift cars. It has to work in conjunction with<br \/>\nMicroEngine 32 Relay Output Extension Board to form a complete Lift Access Control System.<\/p>\n<ul class=\"list2\">\n<li>Wiegand Interface<\/li>\n<li>Encrypted IP<\/li>\n<li>Firmware Upgrade<\/li>\n<li>Device Discovery<\/li>\n<li>Support 4 lift and Up to 128 Floor Relays<\/li>\n<li>DIN-Rail Form Factor<\/li>\n<\/ul>\n<\/div>\n<div class=\"su-tabs su-tabs-style-default su-tabs-mobile-stack\" data-active=\"1\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-tabs-nav\"><span class=\"\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">Features<\/span><span class=\"\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">Configuration Diagram<\/span><span class=\"\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">Documentation<\/span><span class=\"\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">FAQ<\/span><\/div><div class=\"su-tabs-panes\"><div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"Features\">\n<table class=\"product_1\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"product_1_bg\">\n<td class=\"table_no2\">No<\/td>\n<td>Item<\/td>\n<td>Features<\/td>\n<\/tr>\n<tr>\n<td>1.<\/td>\n<td>No. of Lift<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>2.<\/td>\n<td>No. of Floor<\/td>\n<td>Up to 128 Floors<\/td>\n<\/tr>\n<tr>\n<td>3.<\/td>\n<td>No. of Reader<\/td>\n<td>4 (PLATO Reader)<br \/>\n8 (PLATO Reader via XP-MK800E)<br \/>\n4 (Weigand Reader via XP-WG10S)<\/td>\n<\/tr>\n<tr>\n<td>4.<\/td>\n<td>Connect to Reader<\/td>\n<td>Serial RS485 PLATO-Reader<br \/>\nMax. 4 units for 4 liftsSerial RS485 via Reader Interface Unit:<br \/>\nXP-MK800E &#8211; Max. 4 units for 4 liftsWiegand to Plato RS485 Adaptor:<br \/>\nXP-WG10S &#8211; Max. 4 units for 4 lifts<\/td>\n<\/tr>\n<tr>\n<td>5.<\/td>\n<td>I\/O Interface Module<\/td>\n<td>32 Relay Output Board:<br \/>\nXP-SNET-E32R<br \/>\nMax. 4 units for 128 Relay Outputs<\/td>\n<\/tr>\n<tr>\n<td>6.<\/td>\n<td>Inputs<\/td>\n<td>2<br \/>\n1 Dedicated Fire Alarm<br \/>\n1 Dedicated Tamper Input<\/td>\n<\/tr>\n<tr>\n<td>7.<\/td>\n<td>Card Holder Size<\/td>\n<td>10,000 (16 Digits)<\/td>\n<\/tr>\n<tr>\n<td>8.<\/td>\n<td>Max. Transactions Log<\/td>\n<td>50,000<\/td>\n<\/tr>\n<tr>\n<td>9.<\/td>\n<td>Connect to Software<\/td>\n<td>TCP\/IP<\/td>\n<\/tr>\n<tr>\n<td>10.<\/td>\n<td>Time Setting<\/td>\n<td>255 Time Set &amp; 255 Time Zone<\/td>\n<\/tr>\n<tr>\n<td>11.<\/td>\n<td>Holiday Setting<\/td>\n<td>30 x 1 Set<\/td>\n<\/tr>\n<tr>\n<td>12.<\/td>\n<td>Floor Zone<\/td>\n<td>255<\/td>\n<\/tr>\n<tr>\n<td>13.<\/td>\n<td>Floor Accessibility<\/td>\n<td>255<\/td>\n<\/tr>\n<tr>\n<td>14.<\/td>\n<td>Real Time Clock<\/td>\n<td>With On-Board Battery<\/td>\n<\/tr>\n<tr>\n<td>15.<\/td>\n<td>Power Fail Monitor<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>16.<\/td>\n<td>Processor<\/td>\n<td>PIC32-bit RISC MCU at 80 MHz<\/td>\n<\/tr>\n<tr>\n<td>17.<\/td>\n<td>Data Flash Memory<\/td>\n<td>EEPROM:128 KB, Flash 4 MB<\/td>\n<\/tr>\n<tr>\n<td>18.<\/td>\n<td>Flash<\/td>\n<td>512 KB<\/td>\n<\/tr>\n<tr>\n<td>19.<\/td>\n<td>DIN-Rail Casing Dimension<\/td>\n<td>115 mm (H) x 106 mm (W) x 40 mm (D)<\/td>\n<\/tr>\n<tr>\n<td>20.<\/td>\n<td>Casing Dimension (MP-340)<\/td>\n<td>267 mm(H) x 310mm (W) x 72 mm (D)<\/td>\n<\/tr>\n<tr>\n<td>21.<\/td>\n<td>Power Supply<\/td>\n<td>Input: 240VAC, 1A.<br \/>\nOutput:13.8VDC, 2.8A (max)<\/td>\n<\/tr>\n<tr>\n<td>22.<\/td>\n<td>Power Consumption<\/td>\n<td>Typically 12 VDC, 150mA<br \/>\n(Controller board only)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"Configuration Diagram\">\n<p><a href=\"\/wp-content\/uploads\/sites\/4\/2025\/02\/Conf_Diagram_XP-M4L-SE2_1366.png\" rel=\"lightbox-1\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5594\" src=\"\/wp-content\/uploads\/sites\/4\/2025\/02\/Conf_Diagram_XP-M4L-SE2_1366.png\" alt=\"XP-M4L-SE_Diagram\" width=\"750\" height=\"341\"><\/a><\/p>\n<\/div>\n<div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"Documentation\">\n<table class=\"product_1\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"product_1_bg\">\n<td class=\"table_no2\">No<\/td>\n<td>Documentation<\/td>\n<\/tr>\n<tr>\n<td>1.<\/td>\n<td><a href=\"\/pdf\/DATASHEET-2025_XP-M4L-SE_v4.pdf\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"pdf_img\" src=\"\/wp-content\/uploads\/sites\/4\/2015\/04\/PDF-Icon.jpg\" alt=\"PDF-Icon\" width=\"12\" height=\"12\">&nbsp;Product Brochure: XP-M4L-SE<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"FAQ\">\n<p><strong style=\"font-size: 18px;\">FAQ<\/strong><\/p>\n<div class=\"su-accordion su-u-trim\">\n<div class=\"su-spoiler su-spoiler-style-simple su-spoiler-icon-plus\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span>1. I have purchased XP-M2300i and I need to\u2026<\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">\n<ul>\n<li>To install the controller, follow the wiring connection diagram provided, see article ID:&nbsp;<a href=\"\/kb\/article\/AA-00364\" target=\"_blank\" rel=\"noopener\">AA-00364<\/a><\/li>\n<li>To configure the uplink connection, see article ID:&nbsp;<a href=\"\/kb\/article\/AA-00216\" target=\"_blank\" rel=\"noopener\">AA-00216<\/a>&nbsp;if using network connection, or see article ID:&nbsp;<a href=\"\/kb\/article\/AA-00320\" target=\"_blank\" rel=\"noopener\">AA-00320<\/a>&nbsp;if using RS485 connection.<\/li>\n<\/ul>\n<\/div><\/div>\n<div class=\"su-spoiler su-spoiler-style-simple su-spoiler-icon-plus su-spoiler-closed\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span>2. I have installed XP-M2300i at my site, but how do I configure the controller<\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">\n<ul>\n<li>To reset the controller to factory default setting (Coldstart), see article ID:&nbsp;<a href=\"\/kb\/article\/AA-00304\" target=\"_blank\" rel=\"noopener\">AA-00304<\/a><\/li>\n<li>How to use Auto PIN only to access the door, see article ID:&nbsp;<a href=\"\/kb\/article\/AA-00204\" target=\"_blank\" rel=\"noopener\">AA-00204<\/a><\/li>\n<li>To configure car park application using XP-M2300i, see article ID:&nbsp;<a href=\"\/kb\/article\/AA-00342\" target=\"_blank\" rel=\"noopener\">AA-00342<\/a><\/li>\n<\/ul>\n<\/div><\/div>\n<div class=\"su-spoiler su-spoiler-style-simple su-spoiler-icon-plus su-spoiler-closed\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span>3. Troubleshooting Guide <\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">\n<ul>\n<li>Problem to set the address number for reader and controller, see article ID:&nbsp;<a href=\"\/kb\/article\/AA-00332\" target=\"_blank\" rel=\"noopener\">AA-00332<\/a><\/li>\n<li>What is the default IP address for the XP-M2300i controller, see article ID:&nbsp;<a href=\"\/kb\/article\/AA-00336\" target=\"_blank\" rel=\"noopener\">AA-00336<\/a><\/li>\n<\/ul>\n<\/div><\/div>\n<\/div>\n<h6><\/h6>\n<p>&nbsp;<\/p>\n<\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>XP-M4L-SE-IP Based Lift Access Controller XP-M4L-SE Controller IP Based Lift Access Controller is designed for lift button masking system, control up to 128 floor buttons and 4 lift cars. It has to work in conjunction with MicroEngine 32 Relay Output Extension Board to form a complete Lift Access Control System. Wiegand Interface Encrypted IP Firmware [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":1243,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"template-sidebar.php","meta":{"footnotes":""},"class_list":["post-4740","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages\/4740","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/comments?post=4740"}],"version-history":[{"count":19,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages\/4740\/revisions"}],"predecessor-version":[{"id":5882,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages\/4740\/revisions\/5882"}],"up":[{"embeddable":true,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages\/1243"}],"wp:attachment":[{"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/media?parent=4740"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}