{"id":4005,"date":"2017-06-04T07:18:57","date_gmt":"2017-06-03T23:18:57","guid":{"rendered":"http:\/\/localhost:8080\/microengine\/?page_id=4005"},"modified":"2026-05-05T18:34:16","modified_gmt":"2026-05-05T10:34:16","slug":"m-series-xp-m1000i","status":"publish","type":"page","link":"https:\/\/mewebapp-dev.com\/my\/m-series-xp-m1000i\/","title":{"rendered":"XP-M1000i"},"content":{"rendered":"<h2><strong>XP-M1000i<\/strong><\/h2>\n<div id=\"line\"><\/div>\n<p align=\"center\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/sites\/4\/2017\/06\/M1000i.jpg\" alt=\"xp-m1000i\" class=\"alignleft size-full wp-image-3932\"><\/p>\n<div id=\"content-bg\">\n<p><strong>1 Door IP Access Controller<\/strong><\/p>\n<ul class=\"list2\">\n<li>Encrypted IP<\/li>\n<li>Direct TCP\/IP<\/li>\n<li>High Capacity<\/li>\n<li>Supports Up to 16 Digits<\/li>\n<\/ul>\n<\/div>\n<div class=\"su-tabs su-tabs-style-default su-tabs-mobile-stack\" data-active=\"1\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-tabs-nav\"><span class=\"\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">Features<\/span><span class=\"\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">Configuration Diagram<\/span><span class=\"\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">Documentation<\/span><span class=\"\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">FAQ<\/span><\/div><div class=\"su-tabs-panes\"><div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"Features\">\n<table class=\"product_1\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"product_1_bg\">\n<td class=\"table_no2\">No<\/td>\n<td class=\"table_no3\">Item<\/td>\n<td>Features<\/td>\n<\/tr>\n<tr>\n<td>1.<\/td>\n<td>No. of Doors<\/td>\n<td>1 Door<\/td>\n<\/tr>\n<tr>\n<td>2.<\/td>\n<td>No. of Readers<\/td>\n<td>Max 2 Readers (Plato Readers) &#8211; 1 Entry \/ 1 Exit<\/td>\n<\/tr>\n<tr>\n<td>3.<\/td>\n<td>Wiegang \/ ABA Reader<\/td>\n<td>Yes &#8211; Max 2<\/td>\n<\/tr>\n<tr>\n<td>4.<\/td>\n<td>Connection to PC<\/td>\n<td>IP LAN (10\/100 Base-T) \/ RS485<\/td>\n<\/tr>\n<tr>\n<td>5.<\/td>\n<td>Connection to Readers<\/td>\n<td>RS485 &#8211; Plato Reader Series \/ Wiegand\/ABA<\/td>\n<\/tr>\n<tr>\n<td>6.<\/td>\n<td>Card Holders<\/td>\n<td>10,000 (16 Digits)<\/td>\n<\/tr>\n<tr>\n<td>7.<\/td>\n<td>Transactions<\/td>\n<td>50,000<\/td>\n<\/tr>\n<tr>\n<td>8.<\/td>\n<td>Time Setting<\/td>\n<td>255 Time Sets \/ 255 Time Zone (No Access Level Limits)<\/td>\n<\/tr>\n<tr>\n<td>9.<\/td>\n<td>Holiday<\/td>\n<td>30 (2 sets)<\/td>\n<\/tr>\n<tr>\n<td>10.<\/td>\n<td>Inputs<\/td>\n<td>5 Supervised\/Digital (Switchable) &#8211; 1 Door Sensor + 1 Exit Button, 1 Dedicated Fire Alarm Input, 2 Configurable as Reader Tamper, Emergency Breakglass Monitor or General Purpose<\/td>\n<\/tr>\n<tr>\n<td>11.<\/td>\n<td>Door Relay Output(s)<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>12.<\/td>\n<td>Extra Relay Output(s)<\/td>\n<td>Yes (1) &#8211; Configurable<\/td>\n<\/tr>\n<tr>\n<td>13.<\/td>\n<td>Encrypted IP<\/td>\n<td>Yes &#8211; AES 128<\/td>\n<\/tr>\n<tr>\n<td>14.<\/td>\n<td>Global Anti-Passback<\/td>\n<td>Yes &#8211; Use SNet-GAC<\/td>\n<\/tr>\n<tr>\n<td>15.<\/td>\n<td>Real Time Clock<\/td>\n<td>Yes &#8211; with On Board Battery<\/td>\n<\/tr>\n<tr>\n<td>16.<\/td>\n<td>WAN Support<\/td>\n<td>Yes &#8211; Support Dynamic IP<\/td>\n<\/tr>\n<tr>\n<td>17.<\/td>\n<td>Power Fail Monitor<\/td>\n<td>Yes &#8211; with Power Level Monitoring<\/td>\n<\/tr>\n<tr>\n<td>18.<\/td>\n<td>Firmware Upgrade<\/td>\n<td>Download from Software<\/td>\n<\/tr>\n<tr>\n<td>19.<\/td>\n<td>Diagnostic<\/td>\n<td>Yes &#8211; Using Built in Web Browser<\/td>\n<\/tr>\n<tr>\n<td>20.<\/td>\n<td>Onboard LED Indicators<\/td>\n<td>Yes &#8211; Input, Output, Run, Diagnostic, Error<\/td>\n<\/tr>\n<tr>\n<td>21.<\/td>\n<td>Onboard Buzzer<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>22.<\/td>\n<td>Use with other MicroEngine controllers<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>23.<\/td>\n<td>Processor<\/td>\n<td>Microchip PIC32 &#8211; 32 bit RISC MCU at 80 MHz<\/td>\n<\/tr>\n<tr>\n<td>24.<\/td>\n<td>Memory<\/td>\n<td>Program (FLASH: 512KB); DATA (EEPROM: 128KB, FLASH: 4MB)<\/td>\n<\/tr>\n<tr>\n<td>25.<\/td>\n<td>PCB Board Dimension<\/td>\n<td>160mm (L) x 80mm (W)<\/td>\n<\/tr>\n<tr>\n<td>26.<\/td>\n<td>Casing Dimension<\/td>\n<td>235mm (H) x 227mm (W) x 75mm (D)<\/td>\n<\/tr>\n<tr>\n<td>27.<\/td>\n<td>Power Consumption<\/td>\n<td>Typically 400mA (Controller board only)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"Configuration Diagram\"><a href=\"\/wp-content\/uploads\/sites\/4\/2017\/06\/Configuration-Diagram-M1000I.png\" rel=\"lightbox-0\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/sites\/4\/2017\/06\/Configuration-Diagram-M1000I.png\" alt=\"xp-m1000i\" width=\"700\" class=\"alignleft size-full wp-image-3932\"><\/a><\/div>\n<div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"Documentation\">\n<table class=\"product_1\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"product_1_bg\">\n<td class=\"table_no2\">No<\/td>\n<td>Documentation<\/td>\n<\/tr>\n<tr>\n<td>1.<\/td>\n<td><a href=\"\/pdf\/MSeries_Brochure_Aug_2014.pdf\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/sites\/4\/2015\/04\/PDF-Icon.jpg\" alt=\"PDF-Icon\" width=\"12\" height=\"12\" class=\"pdf_img\"> Product Brochure: XP-M1000i<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"FAQ\">\n<p><strong style=\"font-size: 18px;\">FAQ<\/strong><\/p>\n<div class=\"su-accordion su-u-trim\">\n<div class=\"su-spoiler su-spoiler-style-simple su-spoiler-icon-plus\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span>1. I have purchased XP-M1000i and I need to\u2026<\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">\n<ul>\n<li>To install the controller, follow the wiring connection diagram provided, see article ID: <a href=\"\/kb\/article\/AA-00363\" target=\"_blank\" rel=\"noopener\">AA-00363<\/a><\/li>\n<li>To configure the uplink connection, see article ID: <a href=\"\/kb\/article\/AA-00206\" target=\"_blank\" rel=\"noopener\">AA-00206<\/a> if using network connection, or see article ID: <a href=\"\/kb\/article\/AA-00319\" target=\"_blank\" rel=\"noopener\">AA-00319<\/a> if using RS485 connection<\/li>\n<ul>\n<\/div><\/div>\n<div class=\"su-spoiler su-spoiler-style-simple su-spoiler-icon-plus su-spoiler-closed\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span>2. I have installed XP-M1000i at my site, but how do I configure the controller?<\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">\n<ul>\n<li>To reset the controller to factory default setting (Coldstart), see article ID: <a href=\"\/kb\/article\/AA-00303\" target=\"_blank\" rel=\"noopener\">AA-00303<\/a><\/li>\n<li>How to use Auto PIN only to access the door, see article ID: <a href=\"\/kb\/article\/AA-00204\" target=\"_blank\" rel=\"noopener\">AA-00204<\/a><\/li>\n<li>How can I use Card+Pin Mode, see article ID: <a href=\"\/kb\/article\/AA-00325\" target=\"_blank\" rel=\"noopener\">AA-00325<\/a><\/li>\n<ul>\n<\/div><\/div>\n<div class=\"su-spoiler su-spoiler-style-simple su-spoiler-icon-plus su-spoiler-closed\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span>3. Troubleshooting Guide <\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">\n<ul>\n<li>Problem to set the address number for reader and controller, see article ID: <a href=\"\/kb\/article\/AA-00332\" target=\"_blank\" rel=\"noopener\">AA-00332<\/a><\/li>\n<li>What is the default IP address for the XP-M1000i controller, see article ID: <a href=\"\/kb\/article\/AA-00336\" target=\"_blank\" rel=\"noopener\">AA-00336<\/a><\/li>\n<ul>\n<\/div><\/div>\n<\/div>\n<h6><\/h6>\n<p><a href=\"\/kb\/category\/29\/0\/10\/\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/sites\/4\/2015\/04\/support-button.png\" alt=\"support-button\" width=\"200\" height=\"46\" class=\"alignleft size-full wp-image-3660\"><\/a><\/p>\n<\/div><\/div><\/div><\/ul>\n<\/ul>\n<\/ul>\n<\/ul>\n<\/ul>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>XP-M1000i 1 Door IP Access Controller Encrypted IP Direct TCP\/IP High Capacity Supports Up to 16 Digits<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"template-sidebar.php","meta":{"footnotes":""},"class_list":["post-4005","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages\/4005","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/comments?post=4005"}],"version-history":[{"count":4,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages\/4005\/revisions"}],"predecessor-version":[{"id":5844,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages\/4005\/revisions\/5844"}],"wp:attachment":[{"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/media?parent=4005"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}