{"id":2332,"date":"2015-04-05T16:57:06","date_gmt":"2015-04-05T08:57:06","guid":{"rendered":"http:\/\/localhost:8080\/microengine?page_id=2332"},"modified":"2026-05-05T18:34:46","modified_gmt":"2026-05-05T10:34:46","slug":"xp-m1000x","status":"publish","type":"page","link":"https:\/\/mewebapp-dev.com\/my\/xp-m1000x\/","title":{"rendered":"XP-M1000X"},"content":{"rendered":"<h2><strong>XP-M1000X<\/strong><\/h2>\n<div id=\"line\"><\/div>\n<p align=\"center\"><img decoding=\"async\" src=\"\/images\/product\/M1000x.png\" border=\"0\" class=\"img-responsive\"><\/p>\n<div id=\"content-bg\">\n<strong>XP-M1000X<\/strong> is a Standalone Proximity Card Reader and Controller with Keypad and LCD Display. It can connect to an Exit Reader XP-RDPRX. The system supports up to 1,000 card users with 10,000 transaction records in its memory for Time Control (Time Attendant Mode)<\/div>\n<div class=\"su-tabs su-tabs-style-default su-tabs-mobile-stack\" data-active=\"1\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-tabs-nav\"><span class=\"\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">Features<\/span><span class=\"\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">PC Requirements<\/span><span class=\"\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">FAQ<\/span><\/div><div class=\"su-tabs-panes\"><div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"Features\">\n<table class=\"product_1\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"product_1_bg\">\n<td class=\"table_no2\">No<\/td>\n<td>Features<\/td>\n<td>Functions<\/td>\n<\/tr>\n<tr>\n<td>1.<\/td>\n<td>Card User Memory<\/td>\n<td>1,000 (2,000 in Car Park Access Mode)<\/td>\n<\/tr>\n<tr>\n<td>2.<\/td>\n<td>Transaction Records<\/td>\n<td>10,000 (5,000 in Car Park Access Mode)<\/td>\n<\/tr>\n<tr>\n<td>3.<\/td>\n<td>Single Unit Reader, Keypad &amp; Controller<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>4.<\/td>\n<td>Build-In Card Reader<\/td>\n<td>Yes &#8211; EM Card (Mifare Card Model Available)<\/td>\n<\/tr>\n<tr>\n<td>5.<\/td>\n<td>Access Operation Mode<\/td>\n<td>Card Only, PIN Only, Card + PIN<\/td>\n<\/tr>\n<tr>\n<td>6.<\/td>\n<td>Fingerprint Template Capacity<br \/>\n1:N<\/td>\n<td>No<\/td>\n<\/tr>\n<tr>\n<td>7.<\/td>\n<td>Display<\/td>\n<td>2&#215;16 Character LCD with BackLight<\/td>\n<\/tr>\n<tr>\n<td>8.<\/td>\n<td>Keypad<\/td>\n<td>Epoxy Coated High Durability Keypad<\/td>\n<\/tr>\n<tr>\n<td>9.<\/td>\n<td>Time Set &amp; Time Zone<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>10.<\/td>\n<td>Holiday Dates<\/td>\n<td>30<\/td>\n<\/tr>\n<tr>\n<td>11.<\/td>\n<td>Auto PIN<\/td>\n<td>10 Sets<\/td>\n<\/tr>\n<tr>\n<td>12.<\/td>\n<td>Built-in Real Time Clock with Battery<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>13.<\/td>\n<td>Car Park Mode External Entry Reader<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>14.<\/td>\n<td>Exit Reader<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>15.<\/td>\n<td>Exit Push Button<\/td>\n<td>Yes &#8211; with Time Zone Control<\/td>\n<\/tr>\n<tr>\n<td>16.<\/td>\n<td>Support Wiegand 26-bit Reader<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>17.<\/td>\n<td>Anti-Passback<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>18.<\/td>\n<td>Controller Operation Mode<\/td>\n<td>Access Control, Time Attendance, Car Park<\/td>\n<\/tr>\n<tr>\n<td>19.<\/td>\n<td>Supports Programming Through Keypad<br \/>\n&amp; LCD at the Reader<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>20.<\/td>\n<td>Lock Control, Door Sensor &amp; Exit Button Input<\/td>\n<td>Yes &#8211; Through MAS-RBS Located Inside the Door<\/td>\n<\/tr>\n<tr>\n<td>21.<\/td>\n<td>Configurable Lock Release Time<\/td>\n<td>Yes &#8211; 0-99 secs.<\/td>\n<\/tr>\n<tr>\n<td>22.<\/td>\n<td>Configurable Door Open Time<\/td>\n<td>Yes &#8211; 0-99 secs.<\/td>\n<\/tr>\n<tr>\n<td>23.<\/td>\n<td>Auto Lock Release Time Zone<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>24.<\/td>\n<td>Sensor &amp; Output<\/td>\n<td>Yes &#8211; with External MiO-44, 4 In 4 Out Card<\/td>\n<\/tr>\n<tr>\n<td>25.<\/td>\n<td>Data Flash Memory<\/td>\n<td>No<\/td>\n<\/tr>\n<tr>\n<td>26.<\/td>\n<td>Onboard Buzzer<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>27.<\/td>\n<td>Communication Ports<\/td>\n<td>RS232 \/ RS485<\/td>\n<\/tr>\n<tr>\n<td>28.<\/td>\n<td>Can be Linked to PC for Software Control<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>29.<\/td>\n<td>Power<\/td>\n<td>12VDC<\/td>\n<\/tr>\n<tr>\n<td>30.<\/td>\n<td>Dimension<\/td>\n<td>152mm (H) x 122mm (W) x 32mm (D)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"PC Requirements\">\n<table class=\"product_1\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"product_1_bg\">\n<td class=\"table_no2\">No<\/td>\n<td>System<\/td>\n<td>Requirements<\/td>\n<\/tr>\n<tr>\n<td>1.<\/td>\n<td>CPU (Recommended)<\/td>\n<td>Intel Core i3-3220, 3.3 GHz or Higher<\/td>\n<\/tr>\n<tr>\n<td>2.<\/td>\n<td>RAM (Minimum)<\/td>\n<td>2 GB (3 GB Recommended)<\/td>\n<\/tr>\n<tr>\n<td>3.<\/td>\n<td>OS<\/td>\n<td>Microsoft  Win7\/Win8 Pro, 2003\/2008 Server<br \/>\n(Home &amp; Starter  Editions Not Supported)<\/td>\n<\/tr>\n<tr>\n<td>4.<\/td>\n<td>Microsoft.Net Framework<\/td>\n<td>Yes (Version 3.5)<\/td>\n<\/tr>\n<tr>\n<td>5.<\/td>\n<td>Serial Port<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>6.<\/td>\n<td>USB Port<\/td>\n<td>Optional &#8211; Required for USB Desktop Reader<\/td>\n<\/tr>\n<tr>\n<td>7.<\/td>\n<td>Display (1024 x 768 x 16 Bit Colours)<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>8.<\/td>\n<td>Mouse \/ Keyboard<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>9.<\/td>\n<td>Hard Disk (Free Space)<\/td>\n<td>50 GB<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"FAQ\">\n<p><strong style=\"font-size: 18px;\">FAQ<\/strong><\/p>\n<div class=\"su-accordion su-u-trim\">\n<div class=\"su-spoiler su-spoiler-style-simple su-spoiler-icon-plus\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span>1. I have purchased XP-M1000x and I need to\u2026<\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">\n<ul>\n<li>To install the controller, follow the wiring connection diagram provided, see article ID: <a href=\"\/kb\/article\/AA-00308\" target=\"_blank\" rel=\"noopener\">AA-00308<\/a><\/li>\n<li>To configure the downlink and uplink connection, see article ID: <a href=\"\/kb\/article\/AA-00226\" target=\"_blank\" rel=\"noopener\">AA-00226<\/a> if using network connection, or see article ID: <a href=\"\/kb\/article\/AA-00225\" target=\"_blank\" rel=\"noopener\">AA-00225<\/a> if using RS485 connection<\/li>\n<li>To set the connection using LAN, see article ID: <a href=\"\/kb\/article\/AA-00435\" target=\"_blank\" rel=\"noopener\">AA-00435<\/a> if using MOXA &#8211; NPort\u2019s Web Console or see article ID: <a href=\"\/kb\/article\/AA-00436\" target=\"_blank\" rel=\"noopener\">AA-00436<\/a> is using MOXA &#8211; NPort Administrator<\/li>\n<ul>\n<\/div><\/div>\n<div class=\"su-spoiler su-spoiler-style-simple su-spoiler-icon-plus su-spoiler-closed\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span>2. I have installed XP-M1000x at my site, but how do I configure the controller<\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">\n<ul>\n<li>To reset the controller to factory default setting (Coldstart), see article ID: <a href=\"\/kb\/article\/AA-00222\" target=\"_blank\" rel=\"noopener\">AA-00222<\/a><a><\/a><\/li>\n<p><a><br \/>\n<\/a><\/p>\n<li><a>To change Master PIN, see article ID: <\/a><a href=\"\/kb\/article\/AA-00224\" target=\"_blank\" rel=\"noopener\">AA-00224<\/a><\/li>\n<li>To set the Baudrate Setting on MCI, see article ID: <a href=\"\/kb\/article\/AA-00449\" target=\"_blank\" rel=\"noopener\">AA-00449<\/a><\/li>\n<li>To use AutoPIN with XP-M1000x controller, see article ID: <a href=\"\/kb\/article\/AA-00430\" target=\"_blank\" rel=\"noopener\">AA-00430<\/a><\/li>\n<li>To set the XP-M1000x as Exit reader while XP-RDPRX as Entry reader, see article ID: <a href=\"\/kb\/article\/AA-00306\" target=\"_blank\" rel=\"noopener\">AA-00306<\/a><\/li>\n<li>To set Card+Pin mode, see article ID: <a href=\"\/kb\/article\/AA-00307\" target=\"_blank\" rel=\"noopener\">AA-00307<\/a><\/li>\n<ul>\n<\/div><\/div>\n<div class=\"su-spoiler su-spoiler-style-simple su-spoiler-icon-plus su-spoiler-closed\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span>3. Troubleshooting Guide <\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">\n<ul>\n<li>Unable to enter the Programming Menu, see article ID: <a href=\"\/kb\/article\/AA-00448\" target=\"_blank\" rel=\"noopener\">AA-00448<\/a><\/li>\n<li>Controller status showing down. Check the uplink connection, see article ID: <a href=\"\/kb\/article\/AA-00226\" target=\"_blank\" rel=\"noopener\">AA-00226<\/a><\/li>\n<li>Relay board is not responding. Check the downlink connection, see article ID: <a href=\"\/kb\/article\/AA-00225\" target=\"_blank\" rel=\"noopener\">AA-00225<\/a><\/li>\n<li>EM lock does not release after scan a user card which has been installed to the reader, see article ID: <a href=\"\/kb\/article\/AA-00310\" target=\"_blank\" rel=\"noopener\">AA-00310<\/a><\/li>\n<li>EM lock does not release when exit button is pressed, see article ID: <a href=\"\/kb\/article\/AA-00309\" target=\"_blank\" rel=\"noopener\">AA-00309<\/a><\/li>\n<li>EM lock always in disengage\/release condition, see article ID: <a href=\"\/kb\/article\/AA-00311\" target=\"_blank\" rel=\"noopener\">AA-00311<\/a><\/li>\n<ul>\n<\/div><\/div>\n<\/div>\n<h6><\/h6>\n<p><a href=\"\/kb\/category\/44\/0\/10\/\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/sites\/4\/2015\/04\/support-button.png\" alt=\"support-button\" width=\"200\" height=\"46\" class=\"alignleft size-full wp-image-3660\"> <\/a><\/p>\n<\/div><\/div><\/div><\/ul>\n<\/ul>\n<\/ul>\n<\/ul>\n<\/ul>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>XP-M1000X XP-M1000X is a Standalone Proximity Card Reader and Controller with Keypad and LCD Display. It can connect to an Exit Reader XP-RDPRX. The system supports up to 1,000 card users with 10,000 transaction records in its memory for Time Control (Time Attendant Mode)<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"template-sidebar.php","meta":{"footnotes":""},"class_list":["post-2332","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages\/2332","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/comments?post=2332"}],"version-history":[{"count":15,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages\/2332\/revisions"}],"predecessor-version":[{"id":5845,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages\/2332\/revisions\/5845"}],"wp:attachment":[{"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/media?parent=2332"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}