{"id":2319,"date":"2015-04-05T16:14:25","date_gmt":"2015-04-05T08:14:25","guid":{"rendered":"http:\/\/localhost:8080\/microengine?page_id=2319"},"modified":"2026-05-05T18:37:01","modified_gmt":"2026-05-05T10:37:01","slug":"xp-m2300i","status":"publish","type":"page","link":"https:\/\/mewebapp-dev.com\/my\/xp-m2300i\/","title":{"rendered":"XP-M2300i"},"content":{"rendered":"<h2><strong>XP-M2300i<\/strong><\/h2>\n<div id=\"line\"><\/div>\n<p align=\"center\"><img loading=\"lazy\" decoding=\"async\" width=\"180\" height=\"194\" src=\"\/wp-content\/uploads\/sites\/4\/2015\/04\/XP-M2300i-1.png\" alt=\"xp-m2300i-1\" class=\"alignleft size-full wp-image-3941\"><\/p>\n<div id=\"content-bg\"><strong>2 Door IP Access Controller<\/strong><\/p>\n<ul class=\"list2\">\n<li>Direct IP Lan<\/li>\n<li>Encrypted IP<\/li>\n<li>High Capacity<\/li>\n<li>True 2 Doors \/ 4 Readers Capability<\/li>\n<li>Integration Reader (CCTV)<\/li>\n<\/ul>\n<\/div>\n<div class=\"su-tabs su-tabs-style-default su-tabs-mobile-stack\" data-active=\"1\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-tabs-nav\"><span class=\"\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">Features<\/span><span class=\"\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">Configuration Diagram<\/span><span class=\"\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">Documentation<\/span><span class=\"\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">FAQ<\/span><\/div><div class=\"su-tabs-panes\"><div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"Features\">\n<table class=\"product_1\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"product_1_bg\">\n<td class=\"table_no2\">No<\/td>\n<td>Item<\/td>\n<td>Features<\/td>\n<\/tr>\n<tr>\n<td>1.<\/td>\n<td>No. of Doors<\/td>\n<td>2 Doors<\/td>\n<\/tr>\n<tr>\n<td>2.<\/td>\n<td>No. of Readers<\/td>\n<td>Max 4 Readers (Plato Readers) &#8211; 2 Entry \/ 2 Exit<\/td>\n<\/tr>\n<tr>\n<td>3.<\/td>\n<td>Wiegang \/ ABA Reader<\/td>\n<td>Yes &#8211; Max 2<\/td>\n<\/tr>\n<tr>\n<td>4.<\/td>\n<td>Connection to PC<\/td>\n<td>1. IP LAN (10\/100 Base-T) \/<br \/>\n2. RS485<\/td>\n<\/tr>\n<tr>\n<td>5.<\/td>\n<td>Connection to Readers<\/td>\n<td>1. RS485 &#8211; Plato Reader Series \/<br \/>\n2. Wiegand\/ABA<\/td>\n<\/tr>\n<tr>\n<td>6.<\/td>\n<td>Card Holders<\/td>\n<td>30,000 (16 Digits)<\/td>\n<\/tr>\n<tr>\n<td>7.<\/td>\n<td>Transactions<\/td>\n<td>50,000<\/td>\n<\/tr>\n<tr>\n<td>8.<\/td>\n<td>Time Setting<\/td>\n<td>255 Time Sets \/ 255 Time Zone (No Access Level Limits)<\/td>\n<\/tr>\n<tr>\n<td>9.<\/td>\n<td>Holiday<\/td>\n<td>30 (2 sets)<\/td>\n<\/tr>\n<tr>\n<td>10.<\/td>\n<td>Inputs<\/td>\n<td>10 Supervised\/Digital (Switchable)<\/p>\n<ul>\n<li>2 Door Sensors + 2 Exit Buttons<\/li>\n<li>1 Dedicated Fire Alarm Input<\/li>\n<li>5 Configurable as Reader Tamper, Emergency Breakglass Monitor or General purpose<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>11.<\/td>\n<td>Door Relay Output(s)<\/td>\n<td>Yes (2)<\/td>\n<\/tr>\n<tr>\n<td>12.<\/td>\n<td>Extra Relay Output(s)<\/td>\n<td>Yes (2) &#8211; Configurable<\/td>\n<\/tr>\n<tr>\n<td>13.<\/td>\n<td>Encrypted IP<\/td>\n<td>Yes. AES 128<\/td>\n<\/tr>\n<tr>\n<td>14.<\/td>\n<td>WAN Dynamic IP<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>15.<\/td>\n<td>Real Time Clock<\/td>\n<td>Yes (with On Board Battery)<\/td>\n<\/tr>\n<tr>\n<td>16.<\/td>\n<td>Power Fail Monitor<\/td>\n<td>Yes (with Power Level Monitoring)<\/td>\n<\/tr>\n<tr>\n<td>17.<\/td>\n<td>Firmware Upgrade<\/td>\n<td>Download from Software<\/td>\n<\/tr>\n<tr>\n<td>18.<\/td>\n<td>Diagnostic<\/td>\n<td>Yes &#8211; Using Built in Web Browser<\/td>\n<\/tr>\n<tr>\n<td>19.<\/td>\n<td>Onboard LED Indicators<\/td>\n<td>Yes &#8211; Input, Output, Run, Diagnostic, Error<\/td>\n<\/tr>\n<tr>\n<td>20.<\/td>\n<td>Onboard Buzzer<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>21.<\/td>\n<td>Use with Other MicroEngine controllers<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>22.<\/td>\n<td>Dimension<\/td>\n<td>295mm (H) x 285mm (W) x 80mm (D)<\/td>\n<\/tr>\n<tr>\n<td>23.<\/td>\n<td>Power<\/td>\n<td>240VAC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"Configuration Diagram\"><a href=\"\/wp-content\/uploads\/sites\/4\/2015\/04\/XP-M2300i.png\" rel=\"lightbox-0\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/sites\/4\/2015\/04\/XP-M2300i.png\" alt=\"xp-m2300i\" width=\"700\" class=\"alignleft size-full wp-image-3931\" srcset=\"https:\/\/mewebapp-dev.com\/my\/wp-content\/uploads\/sites\/4\/2015\/04\/XP-M2300i.png 992w, https:\/\/mewebapp-dev.com\/my\/wp-content\/uploads\/sites\/4\/2015\/04\/XP-M2300i-300x154.png 300w\" sizes=\"(max-width: 992px) 100vw, 992px\" \/><\/a><\/div>\n<div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"Documentation\">\n<table class=\"product_1\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"product_1_bg\">\n<td class=\"table_no2\">No<\/td>\n<td>Documentation<\/td>\n<\/tr>\n<tr>\n<td>1.<\/td>\n<td><a href=\"\/pdf\/M_Series_Aug_2016.pdf\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/sites\/4\/2015\/04\/PDF-Icon.jpg\" alt=\"PDF-Icon\" width=\"12\" height=\"12\" class=\"pdf_img\"> Product Brochure: XP-M2300i<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"FAQ\">\n<p><strong style=\"font-size: 18px;\">FAQ<\/strong><\/p>\n<div class=\"su-accordion su-u-trim\">\n<div class=\"su-spoiler su-spoiler-style-simple su-spoiler-icon-plus\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span>1. I have purchased XP-M2300i and I need to\u2026<\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">\n<ul>\n<li>To install the controller, follow the wiring connection diagram provided, see article ID: <a href=\"\/kb\/article\/AA-00364\" target=\"_blank\" rel=\"noopener\">AA-00364<\/a><\/li>\n<li>To configure the uplink connection, see article ID: <a href=\"\/kb\/article\/AA-00216\" target=\"_blank\" rel=\"noopener\">AA-00216<\/a> if using network connection, or see article ID: <a href=\"\/kb\/article\/AA-00320\" target=\"_blank\" rel=\"noopener\">AA-00320<\/a> if using RS485 connection.<\/li>\n<ul>\n<\/div><\/div>\n<div class=\"su-spoiler su-spoiler-style-simple su-spoiler-icon-plus su-spoiler-closed\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span>2. I have installed XP-M2300i at my site, but how do I configure the controller<\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">\n<ul>\n<li>To reset the controller to factory default setting (Coldstart), see article ID: <a href=\"\/kb\/article\/AA-00304\" target=\"_blank\" rel=\"noopener\">AA-00304<\/a><\/li>\n<li>How to use Auto PIN only to access the door, see article ID: <a href=\"\/kb\/article\/AA-00204\" target=\"_blank\" rel=\"noopener\">AA-00204<\/a><\/li>\n<li>To configure car park application using XP-M2300i, see article ID: <a href=\"\/kb\/article\/AA-00342\" target=\"_blank\" rel=\"noopener\">AA-00342<\/a><\/li>\n<ul>\n<\/div><\/div>\n<div class=\"su-spoiler su-spoiler-style-simple su-spoiler-icon-plus su-spoiler-closed\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span>3. Troubleshooting Guide <\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">\n<ul>\n<li>Problem to set the address number for reader and controller, see article ID: <a href=\"\/kb\/article\/AA-00332\" target=\"_blank\" rel=\"noopener\">AA-00332<\/a><\/li>\n<li>What is the default IP address for the XP-M2300i controller, see article ID: <a href=\"\/kb\/article\/AA-00336\" target=\"_blank\" rel=\"noopener\">AA-00336<\/a><\/li>\n<ul>\n<\/div><\/div>\n<\/div>\n<h6><\/h6>\n<p><a href=\"\/kb\/category\/30\/0\/10\/\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/sites\/4\/2015\/04\/support-button.png\" alt=\"support-button\" width=\"200\" height=\"46\" class=\"alignleft size-full wp-image-3660\"><\/a><\/p>\n<\/div><\/div><\/div><\/ul>\n<\/ul>\n<\/ul>\n<\/ul>\n<\/ul>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>XP-M2300i 2 Door IP Access Controller Direct IP Lan Encrypted IP High Capacity True 2 Doors \/ 4 Readers Capability Integration Reader (CCTV)<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"template-sidebar.php","meta":{"footnotes":""},"class_list":["post-2319","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages\/2319","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/comments?post=2319"}],"version-history":[{"count":17,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages\/2319\/revisions"}],"predecessor-version":[{"id":5847,"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/pages\/2319\/revisions\/5847"}],"wp:attachment":[{"href":"https:\/\/mewebapp-dev.com\/my\/wp-json\/wp\/v2\/media?parent=2319"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}